Personal ultraviolett-B dosimetry at Koldewey-Station by using an electronic dosimeter ELUV-14.


Contact
selnaggar [ at ] awi-bremerhaven.de

Abstract

Personal exposure of ultraviolet-B irradiance (UV-B) was measured by small portable dosimeter (ELUV-14) at Koldewey-Station in Ny-Ålesund, from May 15 to August 15, 1999. While ten persons carried those dosimeters global irradiance was simultaneously measured by a UV-B spectral radiometer. The highest erythemal weighted global UV-B dose was 2200 J/m2 recorded on June 8, 1999. The personal related maximum value was about 345 J/m2 on May 25, 1999. This corresponds to approximately 23% of the global dose recorded at the same day.



Item Type
Article
Authors
Divisions
Programs
Publication Status
Published
Eprint ID
4502
Cite as
El Naggar, S. E. D. , Gernandt, H. , Spelten, N. and Klaas, A. (2001): Personal ultraviolett-B dosimetry at Koldewey-Station by using an electronic dosimeter ELUV-14. , Environmental research in the Arctic 2000 : proceedings of the Second International Symposium on Environmental Research in the Arctic and Fifth Ny-Ålesund Scientific Seminar ; 23-25 February, NIPR, Tokyo / ed. by Okitsugu Watanabe... Tokyo : National Ins .


Share
Add to AnyAdd to TwitterAdd to FacebookAdd to LinkedinAdd to PinterestAdd to Email

Research Platforms

Campaigns
N/A


Actions
Edit Item Edit Item